Re: [Paddlewise] Rule 800 rules! (was waterbuster

From: Bob Volin <bobvolin_at_bestweb.net>
Date: Wed, 13 Oct 1999 08:12:31 -0400
Here's a brief addendum to my long (sorry) description of the Rule 500
systems I installed.
  I experimented with two kinds of check valves and settled on a modified
1/2 inch pvc valve designed for home plumbing systems. It can be found in
well-stocked hardware or plumbing supply stores.
  This check valve is spring-loaded and will provide a reliable barrier
against back flow into the boat.  The problem is that the valve is designed
for an opening pressure of 200 psi.  In tests, I found that the pump could
handle it, but that the flow was restricted.  I modified the valve by
unscrewing the spring cap, cutting the spring roughly in half, bending the
cut tip to fit the cap, then putting it all back together.  This cut the
opening pressure acceptably.

***************************************************************************
PaddleWise Paddling Mailing List - All postings copyright the author and not
to be reproduced outside PaddleWise without author's permission
Submissions:     paddlewise_at_lists.intelenet.net
Subscriptions:   paddlewise-request_at_lists.intelenet.net
Website:         http://www.paddlewise.net/
***************************************************************************